Sprayable Sound Dampening Standard Operating Procedure (SOP)
Follow SEM's four-step Sprayable Sound Dampening Standard Operating Procedure (SOP) for proper application.
1. PREP
Clean with SEM Solve or Zero VOC Surface Cleaner. Wipe clean in one direction with clean, lint-free cloth.
2. SAND
Sand primer with P180 grit. Sand bare metal with P80 grit. Blow off and tack clean. Re-clean with SEM Solve or Zero VOC Surface Cleaner. Wipe clean in one direction with clean, lint-free cloth.
3. SET UP EQUIPMENT
Place Dual-Mix™ Sound & Seal Sprayable Coating into Universal Pneumatic Applicator. Equalize cartridge until sides dispense equally. Attach Quick Spray System to cartridge.
Note: Do not cut static mixer tip.
4. APPLY
Apply to necessary areas, duplicating existing texture in one coat.
Note: Do not apply over self etching primer.
Tip: To acheive various textures, modify the air pressure, spray distance and spray tip.